Lab equipment · PLC training station

Basic CPU Module

Beckhoff CX9020 embedded PC running a PLC training kit with sensors, actuators and motors — the station where students wire, program and watch industrial control loops come alive.

In service S/N DK-1US-01 GEL572
SENSOR SWITCH PWR TC HDD LINK CX9020 EMBEDDED PLC MOTOR CYLINDER

The controller

Beckhoff CX9020 embedded PC: front panel with two Ethernet ports, four USB ports, RS485 and DVI connectors, status LEDs and the 24 V power terminal block
Beckhoff CX9020 — Arm Cortex-A8 embedded PC on a DIN rail, with its 24 V power supply terminal.Manufacturer page ↗
ProcessorArm Cortex-A8 · 1 GHz
Memory1 GB DDR3 RAM
Storage2 × microSD slots
Ethernet2 × RJ45 10/100 Mbit/s
USB · Video4 × USB 2.0 · 1 × DVI-D
SoftwareWindows Embedded Compact 7 + TwinCAT
Supply24 V DC · ≈5 W
Size · Weight84 × 100 × 91 mm · 590 g
Operating temp.−25 … +60 °C

Identification plate

Equipment
Basic CPU ModulePLC training kit with sensors, actuators and motors
Brand · Model
BECKHOFF CX9020
Serial number
DK-1US-01
Supplier
Labise
USEK ref. no.
Provided by USEK Laboratories
Location
Building H · Floor B1 · Room Hs 105
Department
Electrical, Telecom & Computer Engineering

Educational & research use

Lab course
GEL572
Lab course using this station
Research topics
—
None assigned at present; ask the coordinator to propose one

Safety information

Hazard — electrocution

The kit is fed from a 220 V mains supply. Never touch terminals, open wiring or the power block while the station is energised. The kit’s power supply steps this down to the 24 V DC that feeds the CX9020.

Precautions

No knocks or shocks to the screen, and no disassembly of the kit. Report any damage to the coordinator before use.

How to use the station

1

Look before you power

Check that the CX9020 is clipped on its DIN rail, that every terminal, sensor and actuator cable is seated and none is pinched or bare, and that nothing rests on the screen. Damage found now is the coordinator's problem, not yours — report it and do not switch on.

2

Switch on

Turn on the kit's mains supply. The 24 V DC feed starts the controller automatically: the operating system boots and every connected I/O module is configured. Wait for PWR to settle to steady green and HDD to stop flickering before you do anything else (about a minute).

3

Connect your PC

Plug an Ethernet cable into port X000 or X001. The controller takes its address by DHCP and answers to the host name CX-xxxxxx, where xxxxxx are the last three bytes of the MAC address printed on the nameplate.

To check it is alive, open https://CX-xxxxxx/config in a browser (Beckhoff Device Manager). The lab coordinator provides the login.

4

Open TwinCAT and pick the target

In TwinCAT 3 create or open your project, then SYSTEM › Choose Target › Search (Ethernet) and select the CX9020 by host name. Once linked, the TC LED reports the controller's mode from your PC's point of view.

5

Configure, then run

Scan or declare the kit's I/O, write your PLC program, and Activate Configuration: the controller goes to Config mode (TC blue). Login and Start put it in Run mode (TC green). Watch the sensor and actuator behaviour on the bench, not only in the online view.

Keep hands clear of the motor and cylinder whenever the program is running.
6

Stop and shut down properly

Stop the PLC in TwinCAT, shut down the operating system from the Device Manager or TwinCAT, then switch off the mains. Never cut the power first, and never remove a microSD card while the controller is on — the program image lives on it.

Leave the station as you found it: cables tidy, PC disconnected, bench clear.

Reading the status LEDs

Tap a lamp — the same four LEDs sit on the front of the CX9020.

Do & don't

Do

  • Work with a trained person nearby during your first sessions.
  • Keep the 30 mm ventilation gap above and below the controller free.
  • Save your TwinCAT project on your own drive before you leave.
  • Log anything unusual — a red LED, a hot module, a stuck actuator — with the coordinator.

Don't

  • Never touch wiring or terminals while the kit is energised.
  • Never reverse supply polarity or disconnect 0 V while powered.
  • Never open, unclip or disassemble any module.
  • Never pull the microSD card or the power with the controller running.

This is a quick-start guide. The station's SOP and the USEK Laboratory Guidelines take precedence wherever they differ.

Before you start

0 / 5

This checklist is a personal reminder on your phone — it does not replace the coordinator's sign-off.

Labs Equipment Coordinator

HA
Hady Achkouty
Lab area coordinator / lab technician
OfficeHs 103A
Phone / ext.09 600 953 · ext. 1953